        12.1.7 Crosshead speed (rate of grip separation),
        12.1.8 Gage length (if different from grip separation),
        12.1.9 Type of grips used, including facing (if any),
        12.1.10 Conditioning procedure (test conditions, temperature,
        and relative humidity if nonstandard),
        12.1.11 Anomalous behavior such as tear failure and failure
        at a grip,
        12.1.12 Average breaking factor and standard deviation,
        12.1.13 Average tensile strength (nominal) and standard
        deviation,
        12.1.14 Average tensile strength at break (nominal) and
        standard deviation,
        12.1.15 Average percent elongation at break and standard
        deviation,
        12.1.16 Where applicable, average tensile energy to break
        and standard deviation,
        12.1.17 In the case of materials exhibiting “yield” phenomenon:
        average yield strength and standard deviation; and
        average percent elongation at yield and standard deviation,
        12.1.18 For materials which do not exhibit a yield point:
        average —% offset yield strength and standard deviation; and
        average percent elongation at —% offset yield strength and
        standard deviation,
        12.1.19 Average modulus of elasticity and standard deviation
        (if secant modulus is used, so indicate and report strain at
        which calculated), and
        12.1.20 When an extensometer is employed, so indicate.
        13. Precision and Bias
        13.1 Two interlaboratory tests have been run for these
        tensile properties. The first was run for modulus only, in 1977,
        in which randomly drawn samples of four thin (; 0.025 mm
        (0.001-in.)) materials were tested with five specimens in each
        laboratory. Elastic (tangent) modulus measurements were
        made by six laboratories, and secant (1 %) modulus measurements
        were taken by five laboratories. The relative precision
        obtained in this interlaboratory study is in Table 2.
        13.1.1 In deriving the estimates in Table 2, statistical
        outliers were not removed, in keeping with Practice E 691.9
        13.1.2 The within-lab standard deviation of a mean value, S
        x? , in each case was determined from the standard deviation, S
        x? , of the five individual specimens as follows: S x? = Sx /(5)1?2.
        The S x? values were pooled among laboratories for a given
        material to obtain the within-lab standard deviation, Sr , of a
        test result (mean of five specimens). See 13.3-13.3.2 for
        definitions of terms in the tables.
        13.2 An interlaboratory test was run for all the other tensile
        properties except modulus in 1981, in which randomly drawn
        samples of six materials (one of these in three thicknesses)
        ranging in thickness from 0.019 to 0.178 mm (0.00075 to 0.007
        in.) were tested in seven laboratories. A test result was defined
        as the mean of five specimen determinations. However, each
        laboratory tested eight specimens, and the S x? was determined
        from S x? = Sx /(5)1?2 as above. This was done to improve the
        quality of the statistics while maintaining their applicability to
        a five-specimen test result. The materials and their thicknesses
        are identified in Tables 3-7, each of which contain data for one
        of the following properties: tensile yield stress, yield elongation,
        tensile strength, tensile elongation at break, and tensile
        9 Supporting data are available from ASTM Headquarters. Request RR: D20-
        1084.
        TABLE 3 Precision Data for Yield Stress
        Material Thickness, mils Average, 103 psi (Sr)A 103 psi (SR)B 103 psi I(r)C 103 psi I(R)D 103 psi
        LDPE 1.0 1.49 0.051 0.13 0.14 0.37
        HDPE 1.0 4.33 0.084 0.16 0.24 0.44
        PP 0.75 6.40 0.13 0.52 0.37 1.46
        PC 4.0 8.59 0.072 0.29 0.20 0.82
        CTA 5.3 11.4 0.12 0.50 0.34 1.43
        PET 4.0 14.3 0.12 0.23 0.34 0.66
        PET 2.5 14.4 0.14 0.54 0.40 1.52
        PET 7.0 14.4 0.13 0.36 0.37 1.03
        A S r is the within-laboratory standard deviation of the average.
        B SR is the between-laboratories standard deviation of the average.
        C Ir = 2.83 Sr.
        D I R = 2.83 SR.